AMS 4902
Commercially pure titanium sheet, strip and plate associated with Grade 2.
Commercially Pure Titanium Flat Products
AMS4902M (2023 publisher revision)
1 linked material grade
Material requirements.
Clearly organized.
Commercially pure titanium sheet, strip and plate associated with Grade 2.
Annealed.
Find your material grade
Open a material page or switch between chemical composition and mechanical properties.
Chemical & Mechanical Properties
Select a table to compare the source-labelled material data.
| Grade / identification | Ti % | Fe % | O % | C % | N % | H % |
|---|---|---|---|---|---|---|
| Titanium Grade 2 R50400 | Balance | 0.30 max | 0.25 max | 0.08 max | 0.03 max | 0.015 max |
Manufacturer flat-product composition limits, mass %; verify the specified AMS revision.
These published alloy values are comparison data. The AMS 4902 acceptance limits must be checked in the specified revision.
| Grade / identification | Product form / condition | Tensile (MPa) | 0.2% proof / yield (MPa) | Elongation (%) | Data basis |
|---|---|---|---|---|---|
| Titanium Grade 2 R50400 | Sheet / strip; ATI published product data | 345 min | 275–450 | 20 min | Manufacturer product limits; check the ordered AMS revision and size. |
Typical properties are comparison values. Manufacturer limits marked “min” apply only to the stated product. Confirm the ordered revision, thickness, heat treatment, specimen direction and gauge length before material acceptance.
Engineered for demanding service.
Grade selection depends on the process environment, temperature, corrosion exposure and equipment design.
From material specification to gasket construction
Select the required product form, grade, delivery condition and certification for the approved gasket construction. Finished gasket dimensions and performance requirements are established separately.
Explore gasket products ↗Common questions
Short answers for engineers and purchasing teams.
How should AMS 4902 be specified?
State the revision, exact material grade, product form, dimensions, delivery condition and certification requirements on the purchase order.
Are the displayed properties specification acceptance limits?
The tables identify published manufacturer reference data. Typical values describe the stated reference product and are not certified AMS 4902 limits. Use the ordered revision for material acceptance.
Are these all the materials covered by the standard?
This page links selected materials already present on the website. The linked material list is not the complete scope of the standard.