Inconel 625 · DIN EN 10095
Inconel 625 is presented here as NiCr22Mo9Nb (2.4856) under DIN EN 10095. Heat-resisting steel and nickel-alloy flat products for elevated-temperature service.
NiCr22Mo9Nb
Designation: 2.4856
Data edition: DIN EN 10095:2018-12
Inconel 625 2.4856
Inconel 625 is presented here as NiCr22Mo9Nb (2.4856) under DIN EN 10095. Heat-resisting steel and nickel-alloy flat products for elevated-temperature service.
German adoption of EN 10095:1999 with the corrected NiCr15Fe tensile range 550–850 MPa. Data edition: EN 10095:1999, Tables 1, 2 and 6. Flat-product properties only. The existing SS309 and SS310 names lead to EN 1.4833 and EN 1.4845 respectively, commonly associated with 309S and 310S. EN composition limits control these pages. HB is the guidance maximum Brinell hardness. The Inconel 601 row shown is for thicknesses of at least 3 mm, where a numerical elongation requirement is listed.
Related grades
6 material references with DIN EN 10095 data.
Inconel 625 properties
Select a table to compare requirements.
| Element | Mass % |
|---|---|
| C | 0.03–0.10 |
| Si | ≤0.50 |
| Mn | ≤0.50 |
| P | ≤0.020 |
| S | ≤0.015 |
| Cr | 20.0–23.0 |
| Ni | ≥58.0 |
| Mo | 8.0–10.0 |
| N | — |
| Other elements | Fe ≤5.0; Nb + Ta: 3.15–4.15; Al ≤0.40; Ti ≤0.40; Cu ≤0.50; Co ≤1.00 |
Composition is cast analysis in mass %. Values marked ≤ are maxima; paired values are ranges. Ti and Nb expressions use the carbon content by mass. The symbol — means that this table has no limit for that entry.
| Form | Thickness (mm) | Condition | Test direction | Rp0.2 (MPa) | Rp1.0 min (MPa) | Rm (MPa) | A80 min (%) | A min (%) | Other requirements |
|---|---|---|---|---|---|---|---|---|---|
| Flat products | 0.5 ≤ t < 3 | +A | Transverse | 415 | — | 820–1050 | 30 | — | HB ≤240 |
| Flat products | 3 ≤ t < 75 | +A | Transverse | 380 | — | 760–1000 | — | 30 | HB ≤240 |
Room-temperature properties. Rp0.2 and Rp1.0 are minimum proof strengths; Rm is tensile strength. A80 applies below 3 mm thickness; A applies from 3 mm using a proportional gauge length of 5.65√S₀. +AT = solution annealed; +A = annealed; +RA = recrystallization annealed; +P = precipitation hardened. Strength is in MPa (N/mm²).